FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement

Large Image :  FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement Get Best Price

Product Details:
Place of Origin: USA
Brand Name: Fluke
Certification: CE
Model Number: FLUKE373/FLUKE375/FLUKE376/F374/F376FC/F381
Payment & Shipping Terms:
Minimum Order Quantity: 1 PCS
Price: consult for best discount
Packaging Details: Fluke original package
Delivery Time: 2-7 days
Payment Terms: T/T, , Western Union,Paypal,, MoneyGram,, L/C
Supply Ability: 500 Pcs/month
Detailed Product Description
Display Type: Analog And Digital Measuring Current: AC 999.9 A DC 2500 A
Measuring Voltage: To 1000 V Storage Temperature: -40 °C To +60 °C
Operating Temperature: -10 °C To +50 °C Condition: New And Original
High Light:

fluke clamp multimeter

,

fluke multimeter clamp meter

 Fluke 376 Digital Clamp Meter Multimeter 373 375 376 True-RMS AC/DC Clamp Meter With iFlex

 

Overview 

Fluke 376 AC/DC Clamp Meter with iFlex™     

• 1000 A ac and dc current measurement with fixed jaw
• 2500 A ac current measurement with iFlex™ flexible current probe
• 1000 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Frequency measurement to 500 Hz with both jaw and iFlex™
• 60 kΩ resistance measurement with continuity detection
• Min, max, average and inrush recording to capture variations automatically
• 500 mV dc measurement range to interface with other accessories
• 1000 μF capacitance measurement

 

Features:
• iFlex™ flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure,awkward sized conductors and improved wire access
• CAT IV 600 V, CAT III 1000 V safety rating
• Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments
while providing stable readings Work horse clamps with increasedperformance and flexibility

 

Datasheet Of Fluke 376 AC/DC Clamp Meter with iFlex™ 

Electrical Specifications
AC Current via Jaw
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 374 and 375 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
  A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 375 and 376 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 374
375 and 376
6000 Ω
60 kΩ
Resolution 374 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals  
Batteries 2 AA, NEDA 15A, IEC LR6

 

FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement 0

FlukeTrue RMS Digital Clamp Meter Multimeter With IFlex AC/DC Voltage Measurement 1

Contact Details
Yueqing Richuang Automation Equipment Co.,Ltd

Contact Person: sales

Tel: +8618158331966

Send your inquiry directly to us