Send Message

Yueqing Richuang Automation Equipment Co.,Ltd

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsIndustrial Automation Products

6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit

6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit

6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit
6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit 6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit 6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit

Large Image :  6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit Get Best Price

Product Details:
Place of Origin: Germany
Brand Name: Siemens
Certification: ROHS CE
Model Number: 6ES7416-3XS07-0AB0
Payment & Shipping Terms:
Minimum Order Quantity: 1 PCS
Price: consult for best discount
Packaging Details: Siemens original package
Delivery Time: 2-5 days
Payment Terms: T/T, , Western Union,Paypal,, MoneyGram,, L/C
Supply Ability: 20 Pcs/month
Detailed Product Description
Types: SIMATIC CPU 416-3 HW Functional Status: 01
Firmware Version: V7.0 Programming Package: STEP 7 V5.4 Or Higher With HSP 261
Power Loss, Max: 6.5 W DB Size, Max.: 64 Kbyte
High Light:

simatic wincc comfort

,

central processing unit

     Siemens SIMATIC 416 CPU 6ES7416-3XS07-0AB0 S7-400 Central Processing Unit Industrial Automation Products

 

Application

CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.

The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.

An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.

The integrated PROFINET interface of the CPU 416-3 PN/DP implements switch functionality. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.

Note:
Only the interface module 6ES7 964-2AA04-0AB0 can be used.

 
Design

Both CPUs are equipped with the following:

  • Powerful processor:
    The CPUs achieve instruction execution times as low as 0.03 µs per binary instruction.
  • CPU 416-2: 8 MB main memory (of which 4 MB each for program and data);
    CPU 416-3: 16 MB main memory (of which 8 MB each for program and data);
    CPU 416-3 PN/DP: 16 MB main memory (of which 8 MB each for program and data);
    fast main memory for parts of the user program relevant to execution.
  • Flexible expansion:
    Up to 262144 digital and 16384 analog inputs/outputs.
  • Multi-point interface MPI:
    With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbps. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
  • Mode selector switch:
    Designed as toggle switch.
  • Diagnostics buffer:
    The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
  • Real-time clock:
    The date and time are appended to diagnostic messages of the CPU.
  • Memory card:
    For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available.
  • Combined MPI/DP interface and integrated PROFIBUS DP interface (with CPU 416‑2 and CPU 416‑3):
    The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming).
    Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master acc. to EN 50170.

CPU 416-3 and CPU 416-3 PN/DP also include:

  • 1 module slot:
    Using the IF 964-DP interface module, an additional PROFIBUS DP master system can be connected.

CPU 416-3 PN/DP additionally includes:

  • PROFINET interface with 2 ports (switch):
    • PROFINET IO, 256 IO devices connectable
    • PROFINET CBA
Function
  • Block protection:
    A password concept protects the user program from unauthorized access.
  • Integral HMI services:
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
  • Integrated communications functions:
    • PG/OP communication
    • Shared data communication
    • S7 standard communication
    • S7 communication
  • Firmware update using network

CPU 416-3 PN/DP additional:

  • Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
  • Distributed intelligence in Component Based Automation (CBA) on PROFINET
  • Additional diagnostic options with integrated web server
Parameterizable attributes

The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

  • Multi-point interface MPI:
    • Definition of station addresses.
    • Startup/cycle behavior
    • Stipulation of the maximum cycle time and communications load
  • Address assignment:
    Addressing of I/O modules.
  • Retentive ranges:
    Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
  • Size of the process image, local data.
  • Length of the diagnostics buffer
  • Protection level:
    Definition of access authorization for program and data
  • System diagnostics:
    Definition of the handling and scope of diagnostic messages
  • Timed interrupts:
    Setting of periodicity

Technical specifications

Article number

6ES7416-2XP07-0AB0

6ES7416-3XS07-0AB0

6ES7416-3ES07-0AB0

 

CPU 416-2, MPI, PROFIBUS, 8 MB

CPU 416-3, 16 MB, 3 INTERFACES

CPU416-3 PN/DP, 16 MB, 3 INTERFACES

General information      
Product type designation CPU 416-2 CPU 416-3 CPU 416-3 PN/DP
HW functional status 01 01 01
Firmware version V7.0 V7.0 V7.0
Engineering with      
  • ● Programming package

STEP 7 V5.4 or higher with HSP 261 STEP 7 V5.4 or higher with HSP 261 STEP 7 V5.5 or higher with HSP 262
CiR – Configuration in RUN      
CiR synchronization time, basic load 100 ms 100 ms 100 ms
CiR synchronization time, time per I/O byte 10 µs 10 µs 10 µs
Supply voltage      
Rated value (DC)      
  • ● 24 V DC

No; Power supply via system power supply No; Power supply via system power supply No; Power supply via system power supply
Input current      
from backplane bus 5 V DC, typ. 0.9 A 1.1 A 1.3 A
from backplane bus 5 V DC, max. 1.1 A 1.3 A 1.6 A
from backplane bus 24 V DC, max. 300 mA; 150 mA per DP interface 450 mA; 150 mA per DP interface 300 mA; 150 mA per DP interface
from interface 5 V DC, max. 90 mA; At each DP interface 90 mA; At each DP interface 90 mA; At each DP interface
Power loss      
Power loss, typ. 4.5 W 5.5 W 6.5 W
Power loss, max. 5.5 W 6.5 W 8 W
Memory      
Type of memory RAM RAM RAM
Work memory      
  • ● integrated

8 Mbyte 16 Mbyte 16 Mbyte
  • ● integrated (for program)

4 Mbyte 8 Mbyte 8 Mbyte
  • ● integrated (for data)

4 Mbyte 8 Mbyte 8 Mbyte
  • ● expandable

No No No
Load memory      
  • ● expandable FEPROM

Yes; with Memory Card (FLASH) Yes; with Memory Card (FLASH) Yes; with Memory Card (FLASH)
  • ● expandable FEPROM, max.

64 Mbyte 64 Mbyte 64 Mbyte
  • ● integrated RAM, max.

1 Mbyte 1 Mbyte 1 Mbyte
  • ● expandable RAM

Yes; with Memory Card (RAM) Yes; with Memory Card (RAM) Yes; with Memory Card (RAM)
  • ● expandable RAM, max.

64 Mbyte 64 Mbyte 64 Mbyte
Backup      
  • ● present

Yes Yes Yes
  • ● with battery

Yes; all data Yes; all data Yes; all data
  • ● without battery

No No No
Battery      
Backup battery      
  • ● Backup current, typ.

180 µA; up to 40 °C 180 µA; up to 40 °C 180 µA; up to 40 °C
  • ● Backup current, max.

850 µA 850 µA 850 µA
  • ● Backup time, max.

Dealt with in the module data manual with the secondary conditions and the factors of influence Dealt with in the module data manual with the secondary conditions and the factors of influence Dealt with in the module data manual with the secondary conditions and the factors of influence
  • ● Feeding of external backup voltage to CPU

5 V DC to 15 V DC 5 V DC to 15 V DC 5 V DC to 15 V DC
CPU processing times      
for bit operations, typ. 12.5 ns 12.5 ns 12.5 ns
for word operations, typ. 12.5 ns 12.5 ns 12.5 ns
for fixed point arithmetic, typ. 12.5 ns 12.5 ns 12.5 ns
for floating point arithmetic, typ. 25 ns 25 ns 25 ns
CPU-blocks      
DB      
  • ● Number, max.

10 000; Number range: 1 to 16000 10 000; Number range: 1 to 16000 10 000; Number range: 1 to 16000
  • ● Size, max.

64 kbyte 64 kbyte 64 kbyte
FB      
  • ● Number, max.

5 000; Number range: 0 to 7999 5 000; Number range: 0 to 7999 5 000; Number range: 0 to 7999
  • ● Size, max.

64 kbyte 64 kbyte 64 kbyte
FC      
  • ● Number, max.

5 000; Number range: 0 to 7999 5 000; Number range: 0 to 7999 5 000; Number range: 0 to 7999
  • ● Size, max.

64 kbyte 64 kbyte 64 kbyte
OB      
  • ● Number, max.

see instruction list see instruction list see instruction list
  • ● Size, max.

64 kbyte 64 kbyte 64 kbyte
  • ● Number of free cycle OBs

1; OB 1 1; OB 1 1; OB 1
  • ● Number of time alarm OBs

8; OB 10-17 8; OB 10-17 8; OB 10-17
  • ● Number of delay alarm OBs

4; OB 20-23 4; OB 20-23 4; OB 20-23
  • ● Number of cyclic interrupt OBs

9; OB 30-38 (shortest cycle that can be set = 500 µs) 9; OB 30-38 (shortest cycle that can be set = 500 µs) 9; OB 30-38 (shortest cycle that can be set = 500 µs)
  • ● Number of process alarm OBs

8; OB 40-47 8; OB 40-47 8; OB 40-47
  • ● Number of DPV1 alarm OBs

3; OB 55-57 3; OB 55-57 3; OB 55-57
  • ● Number of isochronous mode OBs

4; OB 61-64 4; OB 61-64 4; OB 61-64
  • ● Number of multicomputing OBs

1; OB 60 1; OB 60 1; OB 60
  • ● Number of background OBs

1; OB 90 1; OB 90 1; OB 90
  • ● Number of startup OBs

3; OB 100-102 3; OB 100-102 3; OB 100-102
  • ● Number of asynchronous error OBs

9; OB 80-88 9; OB 80-88 9; OB 80-88
  • ● Number of synchronous error OBs

2; OB 121, 122 2; OB 121, 122 2; OB 121, 122
Nesting depth      
  • ● per priority class

24 24 24
  • ● additional within an error OB

2 2 2
Counters, timers and their retentivity      
S7 counter      
  • ● Number

2 048 2 048 2 048
Retentivity      
  • — adjustable

Yes Yes Yes
  • — lower limit

0 0 0
  • — upper limit

2 047 2 047 2 047
  • — preset

Z 0 to Z 7 Z 0 to Z 7 Z 0 to Z 7
Counting range      
  • — lower limit

0 0 0
  • — upper limit

999 999 999
IEC counter      
  • ● Number

Unlimited (limited only by RAM capacity) Unlimited (limited only by RAM capacity) Unlimited (limited only by RAM capacity)
S7 times      
  • ● Number

2 048 2 048 2 048
Retentivity      
  • — adjustable

Yes Yes Yes
  • — lower limit

0 0 0
  • — upper limit

2 047 2 047 2 047
  • — preset

No times retentive No times retentive No times retentive
Time range      
  • — lower limit

10 ms 10 ms 10 ms
  • — upper limit

9 990 s 9 990 s 9 990 s
IEC timer      
  • ● present

Yes Yes Yes
  • ● Type

SFB SFB SFB
  • ● Number

Unlimited (limited only by RAM capacity) Unlimited (limited only by RAM capacity) Unlimited (limited only by RAM capacity)

 

6ES7416-3XS07-0AB0 Siemens Simatic S7 400 , 416 CPU Central Processing Unit 0

 

Contact Details
Yueqing Richuang Automation Equipment Co.,Ltd

Contact Person: sales

Tel: +8618158331966

Send your inquiry directly to us