Send Message

Yueqing Richuang Automation Equipment Co.,Ltd

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMotor Control Circuit Breaker

Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector

Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector

Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector
Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector

Large Image :  Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector Get Best Price

Product Details:
Place of Origin: France
Brand Name: Schneider
Certification: UL CE
Model Number: GV3P40 GV3P50 GV3P65
Payment & Shipping Terms:
Minimum Order Quantity: 1 PCS
Price: consult for best discount
Packaging Details: Schneider original package
Delivery Time: 2-5 days
Payment Terms: T/T, Western Union,Paypal, MoneyGram, L/C
Supply Ability: 500
Detailed Product Description
Type: MPCB Device Application: Motor
Poles Description: 3P Network Type: AC
Control Type: Rotary Knob Rated Current: 40 A 50 A 65 A
High Light:

motorized circuit breaker

,

mpcb motor protection circuit breaker

,

IP20 tesys gv3 motor circuit breaker

                 Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector

 

Features

TeSys GV3 motor circuit breaker can be easily integrated within multiple configurations, thanks to its 55 mm standard width and mounting on DIN rail. Conforms to IEC 60947-4-1, IEC/EN 60947-2 and UL 60947-4-1 (transition from UL 508) with complete busbar accessories for quick connection. The new GV3P73 and GV3P80 are extending the range up to 80 A.

GV3P:

  • 9 ratings in total
  • Thermal-Magnetic Breaker
  • Covers 9 to 65 A 5.5 to 45 kW motor with 50 to 100 kA / 400 V breaking capacity

Specifications:

  • Three-position (Start/Stop/Tripped) rotary handle, front face padlocking and other accessories
  • Three-phase, 690 V rated operational voltage (Ue) maximum
  • Operating temperature from -20° C to +60° C open operation
  • IP20 level for finger safe protection
  • Trip test button on front face
  • Common add-on contact and trip blocks and accessories with GV2
  • Patented EverLink creep-compensating technology provides many benefits:
    • Spring-based system ensures a long-lasting power connection
    • Reduce overheating leading to trip and also risk during short circuit
    • Ensure the correct torque tightening each time when you install the products

Benefits

GV3P motor circuit breaker with all its complete accessories can provide you safe and strong connection for your motor equipment. You can:

  • Ensure safety of personnel and motors
  • Maintain reliability of the connection
  • Reduce the time of maintenance
  • Gain the flexibility and cost efficiency
  • Ease cabling for manufacturing

 

Datasheet Of Schneider GV3 Series Motor Control Circuit Breaker

range
TeSys
 
product name
TeSys GV3
 
device short name
GV3P
 
product or component type
Circuit breaker
 
device application
Motor
 
trip unit technology
Thermal-magnetic
 
Complementary
poles description
3P
 
network type
AC
 
utilisation category
AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
 
network frequency
50/60 Hz conforming to IEC 60947-4-1
 
fixing mode
Clipped on 35 mm symmetrical DIN rail
Screwed on panel (with 3 x M4 screws)
 
operating position
Any position
 
motor power kW
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
18.5 kW at 400/415 V AC 50/60 Hz
 
breaking capacity
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
 
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
 
control type
Rotary knob
 
[In] rated current
40 A
 
thermal protection adjustment range
30...40 A
 
magnetic tripping current
560 A
 
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
 
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
 
[Ith] conventional free air thermal current
40 A conforming to IEC 60947-4-1
 
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
 
power dissipation per pole
8 W
 
mechanical durability
50000 cycles
 
electrical durability
50000 cycles for AC-3 at 440 V In
 
operating rate
25 cyc/h
 
rated duty
Continuous conforming to IEC 60947-4-1
 
connections - terminals
EverLink BTR screw connectors 2 cable(s) 1...25 mm² solid
EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible without cable end
EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible with cable end
 
tightening torque
5 N.m on EverLink BTR screw connectors for cable 25 mm²
8 N.m on EverLink BTR screw connectors for cable 35 mm²
 
suitability for isolation
Yes conforming to IEC 60947-1
 
phase failure sensitivity
Yes conforming to IEC 60947-4-1
 
height
132 mm
 
width
55 mm
 
depth
136 mm
 
product weight
0.96 kg

Schneider GV3P40 GV3P65 Motor Control Circuit Breaker TeSys GV3 Thermal Magnetic Protector 0

Contact Details
Yueqing Richuang Automation Equipment Co.,Ltd

Contact Person: sales

Tel: +8618158331966

Send your inquiry directly to us