Product Details:
Payment & Shipping Terms:
|
Types: | 3NA Series | Product Brand Name: | SENTRON |
---|---|---|---|
Protection Class IP: | IP20 | Supply Voltage: | 690V At AC 440V At DC |
Environmental Category: | -20 To +50 At 95% Relative Humidity | Warranty: | 12 Months |
High Light: | cartridge type fuse,cooper bussmann fuse |
3NA Series Electrical Safety Fuses 3NA3801 LV HRC fuse link
Application:
LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings, as well as in the switchboards of power supply companies. They therefore protect essential building parts and installations.
LV HRC fuses are fuse systems designed for operation by skilled personnel. There are no constructional requirements for non-interchangeability of rated current and touch protection.
The components and auxiliary equipment are designed in such a way as to ensure the safe replacement of LV HRC fuses or isolation of systems.
LV HRC fuse links are available in the sizes 000, 00, 0, 1, 2, 3, 4 and 4a.
LV HRC fuse links are available in the following operational classes:
LV HRC fuse links are mainly used in LV HRC fuse bases, LV HRC fuse switch disconnectors, LV HRC fuse strips as well as in LV HRC in-line fuse switch disconnectors.
LV HRC signal detectors are used for remote indication that the LV HRC fuse links have been tripped. Three different solutions are available:
Model | ||
Product brand name | SENTRON | |
Product designation | LV HRC fuse link | |
Design of the product | With blade contacts | |
Design of an identification indicator | Front indicators | |
Design of the switching contact | Non-corroding, silver-plated | |
Design of the fuse link | LV HRC fuse link | |
General technical data | ||
Size of fuse system / acc. to DIN EN 60269-1 | NH000 | |
Operating class of the fuse link | gG | |
circuit-breaker / Design | 3NA3 | |
Supply voltage | ||
● at AC / rated value | 500 V | |
● at DC | 250 V | |
Protection class | ||
Protection class IP | IP20, with connected conductors | |
Switching capacity | ||
Switching capacity current | ||
● at DC / acc. to IEC 60947-2 / rated value | 25 kA | |
● acc. to IEC 60947-2 / rated value | 120 kA | |
Dissipation | ||
Power loss [W] | 1.3 W | |
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole | 1.3 W | |
Electricity | ||
Tripping residual / rated value / derated current / at 40 Cel | 5.7 A | |
Current / at AC / rated value | 6 A | |
Diken-export / Let-through energy | DE_3NA_00_500_gG_6 | |
Mechanical Design | ||
Width | ||
● of the enclosure | 21 mm | |
Mounting position | Any, preferably vertical | |
Net weight | 128 g | |
Environmental conditions | ||
Ambient temperature | ||
● minimum | -5 °C | |
● maximum | 40 °C | |
● during storage | Air humidity 90% at 20 °C | |
Environmental category | -20 to +50 at 95% relative humidity | |
Certificates | ||
Reference code | ||
● acc. to DIN EN 61346-2 | F | |
● acc. to DIN EN 81346-2 | F |