Product Details:
Payment & Shipping Terms:
|
Electricity TypeE: | AC/ Dc | Pole: | 3 Pole |
---|---|---|---|
Power Range: | Up To 250 KW | Frequency: | 50/60 HZ |
Application: | Motor Control | Discount Or Not: | Yes |
Highlight: | motor contactor,electrical contactors |
3RT1075-6AP36 AC/DC Electrical Contactors Power Contactor DC Contactor
Overview
Version |
Size |
Rating of three-phase motors at 50 Hz and and 400 V |
Connection method |
Type |
|
---|---|---|---|---|---|
Screw terminals |
Spring-type terminals |
||||
kW |
|||||
Power contactors for switching motors | |||||
AC operation | |||||
Basic unit | S00 | 3 ... 7.5 | ✓ | ✓ | 3RT201.‑.A.0. |
|
✓ | ✓ | 3RT201.‑..P04‑3MA0 | ||
Basic unit | S0 | 4 ... 18.5 | ✓ | ✓ | 3RT202.‑.A.00 |
|
✓ | ✓ | 3RT202.‑.A.04 | ||
|
✓ | ✓ | 3RT202.‑.CL24‑3MA0 | ||
Basic unit | S2 | 18.5 … 37 | ✓ | ✓ | 3RT203.‑.A.00 |
|
✓ | -- | 3RT203.‑1A.04 | ||
|
✓ | ✓ | 3RT203.‑.CL24‑3MA0 | ||
Basic unit | S3 | 37 ... 55 | ✓ | ✓ | 3RT204.‑.A.00 |
|
✓ | -- | 3RT204.‑1A.04 | ||
|
✓ | -- | 3RT204.‑1CL24‑3MA0 | ||
DC operation | |||||
Basic unit | S00 | 3 ... 7.5 | ✓ | ✓ | 3RT201.‑..B4. |
|
✓ | ✓ | 3RT201.‑.FB4. | ||
|
✓ | ✓ | 3RT201.‑..B44‑3MA0 | ||
|
✓ | ✓ | 3RT201.‑.BB4.‑0CC0 | ||
Basic unit | S0 | 4 ... 18.5 | ✓ | ✓ | 3RT202.‑.B.40 |
|
✓ | ✓ | 3RT202.‑.FB40 | ||
|
✓ | ✓ | 3RT202.‑.BB44 | ||
|
✓ | ✓ | 3RT202.‑..B44‑3MA0 | ||
|
✓ | ✓ | 3RT202.‑.BB40‑0CC0 | ||
DC operation for direct control by PLC (coupling relays) | |||||
Basic unit | |||||
|
S00 | 3 ... 5.5 | ✓ | ✓ | 3RT201.‑..B4. |
|
S0 | 4 ... 15 | ✓ | ✓ | 3RT202.‑.KB40 |
S2 | 18.5 … 37 | ✓ | ✓ | 3RT203.‑.KB40 | |
S3 | 37 and 45 | ✓ | ✓ | 3RT204.‑.KB40 | |
AC/DC operation (50/60 Hz AC and DC) | |||||
Basic unit with integrated coil circuit | S0 | 5.5 ... 18.5 | ✓ | ✓ | 3RT202.‑.N.30 |
Basic unit with integrated coil circuit | S2 | 18.5 … 37 | ✓ | ✓ | 3RT203.‑.N.30 |
|
✓ | -- | 3RT203.‑1N.34 | ||
|
✓ | ✓ | 3RT203.‑.NB34‑3MA0 | ||
|
✓ | ✓ | 3RT203.‑.NB30‑0CC0 | ||
Basic unit with integrated coil circuit | S3 | 37 ... 55 | ✓ | ✓ | 3RT204.‑.N.30 |
|
✓ | -- | 3RT204.‑1N.34 | ||
|
✓ | ✓ | 3RT204.‑.NB34‑3MA0 | ||
|
✓ | ✓ | 3RT204.‑.NB30‑0CC0 | ||
Basic unit with conventional operating mechanism | S6 ... S12 | 55 ... 250 | ✓1) | ✓ | 3RT10..‑.A.36 |
Basic unit with solid-state operating mechanism With the option of control via a separate 24 V DC control signal input |
|||||
|
S6 ... S12 | 55 ... 250 | ✓1) | -- | 3RT10..‑.S.36 |
|
✓1) | ✓ | 3RT10..‑.N.36 | ||
|
✓1) | -- |
3RT10..‑.P.35 |
Application 3RT contactors, sizes S00 to S12
Our power range:
IEC/EN 60947‑1,
IEC/EN 60947‑4‑1,
IEC/EN 60947‑5‑1 (auxiliary switches)
Power contactor, AC-3 400 A, 200 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S12 Busbar connections Drive: conventional screw terminal | ||
Product brand name | SIRIUS | |
Product designation | Power contactor | |
Product type designation | 3RT1 | |
General technical data | ||
Size of contactor | S12 | |
Product extension | ||
● function module for communication | No | |
● Auxiliary switch | Yes | |
Surge voltage resistance | ||
● of main circuit rated value | 8 kV | |
● of auxiliary circuit rated value | 6 kV | |
maximum permissible voltage for safe isolation | ||
● between coil and main contacts acc. to EN 60947-1 | 690 V | |
Protection class IP | ||
● on the front | IP00; IP20 on the front with cover / box terminal | |
● of the terminal | IP00 | |
Shock resistance at rectangular impulse | ||
● at AC | 8,5g / 5 ms, 4,2g / 10 ms | |
● at DC | 8,5g / 5 ms, 4,2g / 10 ms | |
Shock resistance with sine pulse | ||
● at AC | 13,4g / 5 ms, 6,5g / 10 ms | |
● at DC | 13,4g / 5 ms, 6,5g / 10 ms | |
Mechanical service life (switching cycles) | ||
● of contactor typical | 10 000 000 | |
● of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 | |
● of the contactor with added auxiliary switch block typical | 10 000 000 | |
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | K | |
Reference code acc. to DIN EN 81346-2 | Q | |
Ambient conditions | ||
Installation altitude at height above sea level | ||
● maximum | 2 000 m | |
Ambient temperature | ||
● during operation | -25 ... +60 °C | |
● during storage | -55 ... +80 °C | |
Main circuit | ||
Number of poles for main current circuit | 3 | |
Number of NO contacts for main contacts | 3 | |
Operating voltage | ||
● at AC-3 rated value maximum | 1 000 V | |
Operating current | ||
● at AC-1 at 400 V | ||
— at ambient temperature 40 °C rated value | 430 A | |
● at AC-1 | ||
— up to 690 V at ambient temperature 40 °C rated value | 430 A | |
— up to 690 V at ambient temperature 60 °C rated value | 400 A | |
— up to 1000 V at ambient temperature 40 °C rated value | 200 A | |
— up to 1000 V at ambient temperature 60 °C rated value | 200 A | |
● at AC-2 at 400 V rated value | 400 A | |
● at AC-3 | ||
— at 400 V rated value | 400 A | |
— at 500 V rated value | 400 A | |
— at 690 V rated value | 400 A | |
— at 1000 V rated value | 180 A | |
● at AC-4 at 400 V rated value | 350 A |