Product Details:
Payment & Shipping Terms:
|
Display Type: | Analog And Digital | Measuring Current: | AC 999.9 A DC 2500 A |
---|---|---|---|
Measuring Voltage: | To 1000 V | Storage Temperature: | -40 °C To +60 °C |
Operating Temperature: | -10 °C To +50 °C | Condition: | New And Original |
High Light: | fluke clamp multimeter,fluke multimeter clamp meter |
Fluke 376 Digital Clamp Meter Multimeter 373 375 376 True-RMS AC/DC Clamp Meter With iFlex
Overview
Fluke 376 AC/DC Clamp Meter with iFlex™
• 1000 A ac and dc current measurement with fixed jaw
• 2500 A ac current measurement with iFlex™ flexible current probe
• 1000 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Frequency measurement to 500 Hz with both jaw and iFlex™
• 60 kΩ resistance measurement with continuity detection
• Min, max, average and inrush recording to capture variations automatically
• 500 mV dc measurement range to interface with other accessories
• 1000 μF capacitance measurement
Features:
• iFlex™ flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure,awkward sized conductors and improved wire access
• CAT IV 600 V, CAT III 1000 V safety rating
• Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments
while providing stable readings Work horse clamps with increasedperformance and flexibility
Electrical Specifications | ||||
AC Current via Jaw | ||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
|||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
|||
AC Current via Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 374 and 375 | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
||
376 | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
|||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||
Resolution | 0.1 A | |||
Accuracy | 2% ± 5 digits | |||
AC Voltage | ||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
DC Voltage | ||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
Accuracy | 1% ± 5 digits | |||
mV dc | ||||
Range | 375 and 376 | 500.0 mV | ||
Resolution | 0.1 mV | |||
Accuracy | 1% ± 5 digits | |||
Frequency via Jaw | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 10 Hz, ≥10 A | |||
10 – 100 Hz, ≥5 A | ||||
100 – 500 Hz, ≥10 A | ||||
Frequency via Flexible Current Probe | ||||
Range | 375 and 376 | 5.0 - 500.0 Hz | ||
Resolution | 0.1 Hz | |||
Accuracy | 0.5% ± 5 digits | |||
Trigger Level | 5 – 20 Hz, ≥ 25 A | |||
20 – 100 Hz, ≥ 20 A | ||||
100 – 500 Hz, ≥ 25 A | ||||
Resistance | ||||
Range | 374 375 and 376 |
6000 Ω 60 kΩ |
||
Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
||
375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
|||
Accuracy | 1% ± 5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
|||
Accuracy | 1% ± 4 digits | |||
Mechanical Specifications | ||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
Weight | 388 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
Environmental Specifications | ||||
Operating Temperature | 10°C – +50°C | |||
Storage Temp | -40°C – +60°C | |||
Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
|||
Operating Altitude | 3000 meters | |||
Storage Altitude | 12,000 meters | |||
EMC | EN 61326-1:2006 | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
|||
Safety Specifications | ||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
|||
Agency Approvals | ||||
Batteries | 2 AA, NEDA 15A, IEC LR6 |
Contact Person: Richuang
Tel: +8618158331966