Product Details:
Payment & Shipping Terms:
|
Application: | Industrial Communication | Production Range: | S7-400 Communication CP443-5 Extended |
---|---|---|---|
Fuction: | Extended For Connection Of SIMATIC S7-400 To PROFIBUS DP | Type Of Supply Voltage: | DC |
Condition: | New And Original | Warranty: | 12 Months |
High Light: | simatic wincc comfort,central processing unit |
6GK7443-5DX05-0XE0 Communications Processor CP 443 Of S7-400 Industrial Automation Products
Overview
Application
The CP 443-5 Extended is the communications processor of the SIMATIC S7-400 for the PROFIBUS bus system.
It relieves the CPU of communication tasks and supports additional connections.
Communication possibilities of the S7-400 using communication modules:
The number of CPs that can be used is dependent on the performance range of the CPU and on the communications services used.
Function
The CP 443-5 Extended provides access to different communication services of the PROFIBUS bus system:
Product type designation | CP 443-5 Extended | |
Communications processor CP 443-5 Extended for connection of SIMATIC S7-400 to PROFIBUS DP, S5-compatible, PG/OP and S7 communication | ||
Transmission rate | ||
Transfer rate | ||
● at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s | |
Interfaces | ||
Number of interfaces / acc. to Industrial Ethernet | 0 | |
Number of electrical connections | ||
● at the 1st interface / acc. to PROFIBUS | 1 | |
Type of electrical connection | ||
● at the 1st interface / acc. to PROFIBUS | 9-pin Sub-D socket (RS485) | |
Supply voltage, current consumption, power loss | ||
Type of voltage / of the supply voltage | DC | |
Supply voltage / 1 / from backplane bus | 5 V | |
Supply voltage | 5 V | |
Relative symmetrical tolerance / at DC | ||
● at 5 V | 5 % | |
Consumed current | ||
● from backplane bus / at DC / at 5 V / typical | 1 A | |
Power loss [W] | 5 W | |
Permitted ambient conditions | ||
Ambient temperature | ||
● during operation | 0 ... 60 °C | |
● during storage | -40 ... +70 °C | |
● during transport | -40 ... +70 °C | |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % | |
Protection class IP | IP20 | |
Design, dimensions and weight | ||
Module format | Compact module S7-400 single width | |
Width | 25 mm | |
Height | 290 mm | |
Depth | 210 mm | |
Net weight | 0.65 kg | |
Product properties, functions, components / general | ||
Number of units | ||
● per CPU / maximum | 14 | |
● Note | The number of CPs that can be operated as DP masters depends on the number of CP 443-1 Advanced processors operating in the S7-400 station as PROFINET IO controllers. Up to 10 CPs can be operated in total: up to 4 as PROFINET IO controllers (CP 443-1 Advanced); up to 10 as DP masters (CP 443-5 Extended) | |
Performance data / open communication | ||
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 32 | |
Amount of data | ||
● as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 240 byte | |
Performance data / PROFIBUS DP | ||
Service / as DP master | ||
● DPV1 | Yes | |
Number of DP slaves / on DP master / usable | 125 | |
Amount of data | ||
● of the address area of the inputs / as DP master / total | 4096 byte | |
● of the address area of the outputs / as DP master / total | 4096 byte | |
● of the address area of the inputs / per DP slave | 244 byte | |
● of the address area of the outputs / per DP slave | 244 byte | |
Performance data / S7 communication | ||
Number of possible connections / for S7 communication | ||
● maximum | 48 | |
Performance data / multi-protocol mode | ||
Number of active connections / with multi-protocol mode | ||
● without DP / maximum | 59 | |
● with DP / maximum | 54 | |
Configuration software | ||
● required | STEP 7 V5.4 SP4 or higher and NCM S7 for PROFIBUS |
Contact Person: Richuang
Tel: +8618158331966